63A AC 220V Din Rail Dual Display Adjustable Over Voltage Current and Under Voltage Protective Device Protector
₨ 1,720
- 1.Model VOLTECK
- 2.Power supply:AC220V 50Hz
- 3.Max.Loading power: AC1~40A Adjustable(default:40A)
- AC1~63A Adjustable(default:63A)
- 4.Overvoltage action cut-off value: 240V-300VAC can be set as a section (default 270VAC)
- 5.Undervoltage action cut-off value: 140V-200VAC, adjustable (default 170VAC)
- 6.Overcurrent action cut-off value: 63A: 1A-63A can be set as a section (default 63A) / 40A: 1A-40A can be set as a section (default 40A)
- 7.Power on and power off delay time: 5-300S adjustable (default 30S)
- 8.Startup delay time: 1-300S adjustable (default 5S)
- 9.Reset delay time after overcurrent protection: 30-300S adjustable (default 30S)
- 10.Delay time for product overcurrent: 6s (overcurrent time greater than this time will be confirmed as overcurrent and protected)
- 11.Self power consumption: ≤ 2W
- 12.Electrical and mechanical life:>100000 times
1.Model1.VOLTECK
2.Power supply:AC220V 50Hz
3.Max.Loading power: AC1~40A Adjustable(default:40A)
AC1~63A Adjustable(default:63A)
4.Overvoltage action cut-off value: 240V-300VAC can be set as a section (default 270VAC)
5.Under voltage action cut-off value: 140V-200VAC, adjustable (default 170VAC)
6.Overcurrent action cut-off value: 63A: 1A-63A can be set as a section (default 63A) / 40A: 1A-40A can be set as a section (default 40A)
7.Power on and power off delay time: 5-300S adjustable (default 30S)
8.Startup delay time: 1-300S adjustable (default 5S)
9.Reset delay time after overcurrent protection: 30-300S adjustable (default 30S)
10.Delay time for product overcurrent: 6s (overcurrent time greater than this time will be confirmed as overcurrent and protected)
11.Self power consumption: ≤ 2W
12.Electrical and mechanical life:>100000 timesol
2.Power supply:AC220V 50Hz
3.Max.Loading power: AC1~40A Adjustable(default:40A)
AC1~63A Adjustable(default:63A)
4.Overvoltage action cut-off value: 240V-300VAC can be set as a section (default 270VAC)
5.Undervoltage action cut-off value: 140V-200VAC, adjustable (default 170VAC)
6.Overcurrent action cut-off value: 63A: 1A-63A can be set as a section (default 63A) / 40A: 1A-40A can be set as a section (default 40A)
7.Power on and power off delay time: 5-300S adjustable (default 30S)
8.Startup delay time: 1-300S adjustable (default 5S)
9.Reset delay time after overcurrent protection: 30-300S adjustable (default 30S)
10.Delay time for product overcurrent: 6s (overcurrent time greater than this time will be confirmed as overcurrent and protected)
11.Self power consumption: ≤ 2W
12.Electrical and mechanical life:>100000 times












Reviews
There are no reviews yet.